OUTPUT
|
ORDER NO.
| GS90A24-P1M
|
SAFETY MODEL NO.
| GS90A24 |
DC VOLTAGE Note.2
| 24V
|
RATED CURRENT
| 3.75A
|
CURRENT RANGE
| 0 ~3.75A
|
RATED POWER
| 90W
|
RIPPLE & NOISE (max.) Note.3
| 180mVp-p
|
VOLTAGE TOLERANCE Note.4
| +/- 3.0%
|
| LINE REGULATION Note.5 | +/- 1.0%
|
LOAD REGULATION Note.6
| +/- 3.0%
|
SETUP, RISE, HOLD TIME Note 8
| 1000ms, 20ms / 230VAC 1000ms, 20ms / 115VAC at full load
|
HOLD UP TIME (Typ.)
| 20ms / 230VAC 20ms / 115VAC at full load
|
INPUT
|
VOLTAGE RANGE Note 9
| 90 ~ 264VAC 135 ~ 370VDC
|
FREQUENCY RANGE
| 47~63Hz
|
POWER FACTOR (Typ.)
| PF>0.91 / 230VAC PF>0.95 / 115VAC at full load
|
EFFICIENCY (Typ.)
| 89.5%
|
AC CURRENT
| 2A / 115VAC 1A / 230VAC
|
INRUSH CURRENT (max.)
| 70A / 230VAC
|
LEAKAGE CURRENT (max.)
| 1mA / 240VAC
|
PROTECTION
|
OVER LOAD
| 110~150% rated output power
Protection type : Hiccup mode, recovers
automatically after fault condition is removed
|
OVER VOLTAGE
| 105~135% rated output voltage
Protection type : Shut down o/p voltage,
re-power on to recover
|
OVER TEMPERATURE
| RTH30 > 100°C Protection type : Shut down o/p voltage, re-power on to recover
|
ENVIRONMENT
|
WORKING TEMP.
| 0~+ 50 (Refer to output load derating curve)
|
WORKING HUMIDITY
| 20%~90% RH non-condensing
|
STORAGE TEMP., HUMIDITY
| -20 ~ +85 , 10 ~ 95% RH
|
TEMP. COEFFICIENT
| +/- 0.03% / (0~50 )
|
VIBRATION
| 10~500Hz, 2G 3AXES 10min./1cycle, period
for 60min. each along X, Y, Z axes
|
SAFETY & EMC (Note. 7)
|
SAFETY STANDARDS
| UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943 approved
|
WITHSTAND VOLTAGE
| I/P-O/P: 3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
|
ISOLATION RESISTANCE
| I/P-O/P, I/P-FG, O/P-FG / 25 / 70% RH :100M Ohms / 500VDC
|
EMI CONDUCTION & RADIATION
| Compliance to EN55022 class B, FCC PART 15 / CISPR22 class B,
CNS13438 class B, GB9254 class B
|
HARMONIC CURRENT
| Compliance to EN61000-3-2,3, GB17625.1
|
EMS IMMUNITY
| Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
|
OTHERS
|
MTBF
| 348.7Khrs min. MIL-HDBK-217F(25 )
|
DIMENSION
| 145*60*32mm (L*W*H)
|
CONNECTOR
|
PLUG
|
Standard type for stock ther type available by customer requested P1M:
2.5 * 5.5 * 11mm, tuning fork type, center positive ; O
|
CABLE
| Standard type 180cm of SPT-1, 18Awg*2c for stock ther type
available by customer requested ;
|
NOTE
|
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated
with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load
7.The power supply is considered a component which will be installed into
a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
8. Length of set up time is measured at first cold start. Turning ON/OFF
the power supply may lead to increase of the set up time.
9. Derating may be needed under low input voltages. Pleas check the derating curve for more details.
|