Back to HTML view



GS90A24-P1M



GS90A24-P1M
Features:
  • Universal AC input / Full range
  • No load power consumption<0.5W
  • Energy star(CEC) level compliant
  • Meet energy star (CEC) draft V2.0 level V
  • Meet EISA 2007(Energy Independence and Security Act)
  • 3 pole AC inlet IEC320-C14
  • Class power ( with earth pin)
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Pass LPS
  • Fully enclosed plastic case
  • LED indicator for power on
  • Approvals: UL / CUL / TUV / BSMI / CCC / CB / FCC / CE
  • 2 years warranty
  • Built-in active PFC function, PF>0.91

Technical Specifications:

Diagram

OUTPUT
ORDER NO.
GS90A24-P1M
SAFETY MODEL NO.
GS90A24
DC VOLTAGE Note.2
24V
RATED CURRENT
3.75A
CURRENT RANGE
0 ~3.75A
RATED POWER
90W
RIPPLE & NOISE (max.) Note.3
180mVp-p
VOLTAGE TOLERANCE Note.4
+/- 3.0%
LINE REGULATION Note.5+/- 1.0%
LOAD REGULATION Note.6
+/- 3.0%
SETUP, RISE, HOLD TIME Note 8
1000ms, 20ms / 230VAC 1000ms, 20ms / 115VAC at full load
HOLD UP TIME (Typ.)
20ms / 230VAC 20ms / 115VAC at full load
INPUT
VOLTAGE RANGE Note 9
90 ~ 264VAC 135 ~ 370VDC
FREQUENCY RANGE
47~63Hz
POWER FACTOR (Typ.)
PF>0.91 / 230VAC PF>0.95 / 115VAC at full load
EFFICIENCY (Typ.)
89.5%
AC CURRENT
2A / 115VAC 1A / 230VAC
INRUSH CURRENT (max.)
70A / 230VAC
LEAKAGE CURRENT (max.)
1mA / 240VAC
PROTECTION
OVER LOAD
110~150% rated output power
Protection type : Hiccup mode, recovers
automatically after fault condition is removed
OVER VOLTAGE
105~135% rated output voltage
Protection type : Shut down o/p voltage,
re-power on to recover
OVER TEMPERATURE
RTH30 > 100°C Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT
WORKING TEMP.
0~+ 50 (Refer to output load derating curve)
WORKING HUMIDITY
20%~90% RH non-condensing
STORAGE TEMP., HUMIDITY
-20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
+/- 0.03% / (0~50 )
VIBRATION
10~500Hz, 2G 3AXES 10min./1cycle, period
for 60min. each along X, Y, Z axes
SAFETY & EMC (Note. 7)
SAFETY STANDARDS
UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943 approved
WITHSTAND VOLTAGE
I/P-O/P: 3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG / 25 / 70% RH :100M Ohms / 500VDC
EMI CONDUCTION & RADIATION
Compliance to EN55022 class B, FCC PART 15 / CISPR22 class B,
CNS13438 class B, GB9254 class B
HARMONIC CURRENT
Compliance to EN61000-3-2,3, GB17625.1
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
OTHERS
MTBF
348.7Khrs min. MIL-HDBK-217F(25 )
DIMENSION
145*60*32mm (L*W*H)
CONNECTOR
PLUG
Standard type for stock ther type available by customer requested P1M:
2.5 * 5.5 * 11mm, tuning fork type, center positive ; O
CABLE
Standard type 180cm of SPT-1, 18Awg*2c for stock ther type
available by customer requested ;
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated
with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load
7.The power supply is considered a component which will be installed into
a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
8. Length of set up time is measured at first cold start. Turning ON/OFF
the power supply may lead to increase of the set up time.
9. Derating may be needed under low input voltages. Pleas check the derating curve for more details.


Back to the section