U65S108-P2J



100-230/24 AC adapter U65S108-P2J

Features:
  • 3 pole AS inlet IEC320-C14
  • Class I power (with earth pin)
  • Protections: Short circuit/ Over load/Ocer voltage
  • Fix switching frequency and regulation
  • LED indicator for power on
  • Fully enclosed plastic case
  • Topology: PWM 3882 circuit
  • Approvals: UL/CUL/TUV/CB/CE
  • 1 year warranty

Technical Specifications:

Diagrams

OUTPUT
ORDER NO.
U65S108-P2J
SAFETY MODEL NO.
SPU65-108
DC VOLTAGE Note.2
24V
RATED CURRENT
3.33A
CURRENT RANGE
0 ~3.33A
RATED POWER
80W
RIPPLE & NOISE (max.) Note.3
150mVp-p
VOLTAGE ADJ. RANGE
Fixed
VOLTAGE TOLERANCE Note.4
+/- 2.0%
LINE REGULATION Note.5+/- 0.5%
LOAD REGULATION Note.6
+/- 1.5%
SETUP, RISE, HOLD TIME
800ms, 50ms, 16ms at full load
INPUT
VOLTAGE RANGE
95 ~ 264VAC 140~370VDC
FREQUENCY RANGE
47~63Hz
EFFICIENCY (Typ.)
78%
AC CURRENT
1.9A / 100VAC
INRUSH CURRENT (max.)
40A / 230VAC
LEAKAGE CURRENT (max.)
0.75mA / 240VAC
PROTECTION
OVER LOAD
110~160% rated output power
Protection type : Hiccup mode, recovers
automatically after fault condition is removed
OVER VOLTAGE
110~140% rated output voltage
Protection type : Shut down o/p voltage,
re-power on to recover
ENVIRONMENT
WORKING TEMP.
0~+ 40 (Refer to output load derating curve)
WORKING HUMIDITY
20%~90% RH non-condensing
STORAGE TEMP., HUMIDITY
-20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
+/- 0.03% / (0~50 )
VIBRATION
10~500Hz, 2G 3AXES 10min./1cycle, period
for 60min. each along X, Y, Z axes
SAFETY & EMC (Note. 7)
SAFETY STANDARDS
UL1950, EN60950 Approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC , I/P-FG:1.5KVAC
ISOLATION RESISTANCE
I/P-O/P I/P-FG , :100M Ohms / 500VDC
EMI CONDUCTION & RADIATION
Compliance to EN55022(CISPR22) class B
HARMONIC CURRENT
Compliance to EN61000-3-2,3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, criteria A Light industry level,
OTHERS
MTBF
100K hrs min. MIL-HDBK-217F (25 )
DIMENSION
168*78.5*44.5mm (L*W*H)
CONNECTOR
PLUG
Standard type P2J: 2.1 * 5.5 * 11mm, center positive for stock ;
Other type available by customer requested
CABLE
Standard type 180cm of SPT-1, 18Awg*2c for stock ther type
available by customer requested ;
NOTE
  1. All parameters are specified at 230VAC input, rated load, 25 °C, 70% RH. Ambient
  2. DC voltage: The output voltage set at point measure by plug terminal & 50% load
  3. Ripple & noise are measured at 20MHz by using 12" twisted pair terminated with a 0.1 μf & 47μf capacitor
  4. Tolerance: Includes setup tolerance, line regulation, load regulation.
  5. Line regulation is measured from low line to high line at rated load
  6. Load regulation is measured from 0% to 100% rated load.
  7. The power supply is considered a component which will be installed
into a final equipment. The final equipment must be re-confirmed that it
still meets EMC directives.


Back to the section